Module de Gaz Datascope SE
zoom_out_map

Datascope SE Gas Module

26112103
Second Hand
€500.00
Tax excluded
Available

Module de Gaz Datascope SE

Supplied with water trap

The Gas Module SE adds state-of-the-art gas monitoring and analysis capabilities to the Datascope Passport 2, Spectrum, and Spectrum OR vital signs monitors. It provides identification and quantification of O2, CO2, N2O, and five anesthetic agents; Halothane, Isoflurane, Sevoflurane, Desflurane, and Enflurane.

WhatsApp Chat

 

Worldwide Delivery

 

After Sales Service Guaranteed

 

Secured Payment

Module de Gaz Datascope SE

Supplied with water trap

The SE Gas Module adds state-of-the-art gas monitoring and analysis capabilities to the Datascope Passport 2, Spectrum, and Spectrum OR vital signs monitors. It provides identification and quantification of O2, CO2, N2O, and five anesthetic agents; Halothane, Isoflurane, Sevoflurane, Desflurane, and Enflurane.

The SE Gas Module is a breath-by-breath gas analyzer, designed to meet the comprehensive anesthesia monitoring requirements of virtually every hospital and freestanding surgical center - whatever its size, specialty, or patient base.

- Compact and lightweight.

- Ideal for all environments - Meets the comprehensive anesthesia monitoring requirements of virtually every hospital and freestanding surgical center.

- Ability to fully integrate into Datascope Passport 2, Spectrum, and Spectrum OR user-interface and displays.

- Breath-by-breath, fast O2, CO2, N2O monitoring with automatic or manually controlled measurement of five anesthetic agents.

- In addition, MAC values can be displayed on the Spectrum OR.

- Spirometry measures patient's airway pressures and lung volumes.

- The numeric data and loops can be displayed on the Spectrum OR.

26112103

Specific References

Second Hand

Dimensions

  • Height: 4.2” (10.6 cm)
  • Width: 11.85” (30.1 cm)
  • Depth: 10” (25.4 cm)
  • Weight: 9.6 lbs (4.35 kg)

Performance

  • Sampling Rate: 200 ± 20 ml/min (with sampling line ≤ 6 meters, under normal conditions)
  • Sampling Delay: 2.5 seconds (with a 3-meter sampling line)
  • Total System Response Time: 2.9 seconds (with a 3-meter sampling line, including sampling delay and rise time)
  • Display Update Rate: Breath-by-Breath
  • Compensation: Automatic for pressure, CO2-N2O and CO2-O2 collision broadening the effect
  • Warm-up Time: Maximum 2 minutes to operation with CO2, O2, and N2O; 5 minutes to the operation of anesthetic agents; 30 minutes for full accuracy specifications
  • Autozeroing Interval: At startup and at 2, 4, 10, 15, 30, 45, and 60 minutes of operation. Every 60 minutes thereafter

Pneumatic

  • Technology: Side-stream gas sampling
  • Pneumatic Modes: Room air reference measurement: Automatic; Sampling system purge: Automatic
  • Pump: Flow controlled dual membrane
  • Gas sampling rate: with DRYLINE™ Water Trap, Adult/Ped: 200 ml/min; with DRYLINE™ Water Trap, Neonate: 120 ml/min
  • Occlusion Alarm: Actual flow < 40 ml/min
  • Room Air Reference Measurement: Automatic when gas measurement bench temperature change is > 1°C or time since last ref. measurement is > 4 h
  • Reference Measurement Interval: ISO Accuracy Mode > 30 s Full Accuracy Mode > 4h
  • Reference Measurement Duration: Typical 5 s, Max 9 s
  • Purge Cycle: Automatic when occlusion detected

Contact us

optional

WhatsApp Chat