PRINCIPLE OF OPERATION

The VAPR system offers four bipolar modes of operation: Vaporization, Desiccation, Mixed Vaporization and Desiccation with temperature indication.

- In the Vaporization operating mode, high frequency power is delivered from the VAPR generator to the electrodes. At specific power thresholds, a vapor pocket, characterized by an orange glow, is created around the active electrode. The arcs within the vapor pocket produce vaporization of the tissue entering the vapor pocket. entering the vapor pocket.

- The vaporization power threshold for a particular VAPR electrode is set automatically by default by connecting the electrode to the power outlet. automatically set by default by connecting the electrode, via the handpiece to the generator. The default setting for each type of electrode is the optimal power required to produce the desired tissue effect. optimal power required to produce the desired tissue effect. As an inherent safety feature, the VAPR system is designed to minimize the power required to maintain the vapor pocket around the active electrode. maintain the vapor pocket around the active electrode.

- In the "desiccation" mode of operation, the VAPR generator delivers high frequency power to the active electrode, which maintains the vapor pocket around the active electrode. frequency to the active electrode to cause tissue desiccation and coagulation without producing sparks or cuts. The desiccation power level is also automatically set as a default for each electrode style.

- The Mixed Vaporization mode of operation allows for tissue vaporization along with hemostasis. combined with hemostasis. Some electrode styles automatically default to the mixed vaporization mode.

- In the temperature-indicating desiccation mode (only available with VAPR Temperature Control (TC) electrodes), the tip temperature is set by default, as well as the power level. by default, as well as the power level. The VAPR system monitors the actual tip temperature during activation and automatically adjusts the power to maintain the tip temperature at the set temperature. to maintain the tip temperature at the set temperature.

INDICATIONS FOR USE

The Mitek VAPR System is intended for the resection, ablation and excision of soft tissue, and hemostasis of blood vessels in patients requiring arthroscopic surgery of the knee, shoulder, ankle, elbow and wrist. Arthroscopic surgery may include, for example

  • Knee: Meniscectomy / Lateral release / Chondroplasty / Synovectomy / ACL debridement / Plica extraction / Meniscal cystectomy
  • Ankle: Fracture debridement / Scar tissue excision / Synovectomy / Chondroplasty
  • Wrist: Synovectomy / Cartilage debridement / Fracture debridement
  • Shoulder: Resection of labrum tear / Synovectomy / Excision of scar tissue / Acromioplasty / Bursectomy / Subacromial decompression / Chondroplasty
  • Elbow: Synovectomy / Tendon debridement / Chondroplasty

30032201

Specific References

Second Hand
  • Dimensions (H x W x D): 3.5 in x 16 in x 14.5 in (9 cm x 41 cm x 36.8 cm)
  • Weight: 12 lb. (5.6kg) approximately

Transport and Storage Conditions

  • Ambient Temperature Range: 32 to 122°F (0 to 50°C)
  • Relative Humidity: 10% to 90%, non condensing
  • Atmospheric Pressure: 500 to l060 millibars

Operating Conditions

  • Ambient Temperature Range: 60 to 104°F (10 to 40°C)
  • Relative Humidity: 10% to 90%, non condensing
  • Atmospheric Pressure: 500 to l060 millibars

Power Supply

  • Regulation Voltage: 90-132 Volts RMS, 198- 264 Volts RMS
  • Operating Range: nominal 100-120/220-240V RMS 50/60Hz
  • Inlet Fuses: Time lag 6.3A (T6A3) 
  • Leakage Currents: Within limits of Class BF equipment as per IEC 60601-1

  • Alarm Volume: Adjustable between 40dB (minimum) and 65dB (maximum) at 1m. This is an activation signal only.
  • Classification: Electrical: Class 1 ordinary equipment as per IEC60601-1.
  • EMC: Group 1 Class A as per IEC60601-1-2.
  • Defibrillator Proof, Type BF equipment with isolated (F) applied part. Each of the electrode terminals of the Generator can withstand the effects of defibrillator discharge.
  • Liquid Spillage as per IEC 60601-2-2. The Generator enclosure will prevent reasonable amounts of liquid from interfering with the Generator’s safe and satisfactory operation.
  • Intermittent Operation
  • The Generator is cooled by natural convection. Under maximum power setting and rated load conditions the Generator is suitable for a 10 seconds on, 30 seconds off duty cycle for 1 hour.

Temperature Control Mode

  • Control range: 45 - 95ºC
  • Display range: 10 - 99ºC
  • Over temp indicator: >8ºC above SET temperature