Diatermo MB 300D Hospital Electrosurgical Unit
zoom_out_map

Diatermo MB 300D Hospital Electrosurgical Unit

N-30634
New product
€5,350.00
attach_money Offer Your Price
Available

Diatermo MB 300D Hospital Electrosurgical Unit

High frequency electrosurgical equipment suitable to deliver current for monopolar cut and coagulated cut (with different levels of coagulation), bipolar cut and coagulation.

Suitable in outpatient surgery, general surgery, pediatric surgery, plastic surgery, thorax surgery, vascular surgery, dermatology, endoscopy, gastroenterology, gyneacology, neurosurgery, orthopedics, otorhinolaringology, pneumology, urology, veterinary

WhatsApp Chat

 

Worldwide Delivery

 

After Sales Service Guaranteed

 

Secured Payment

Diatermo MB 300D Hospital Electrosurgical Unit

High frequency electrosurgical equipment suitable to deliver current for monopolar cut and coagulated cut (with different levels of coagulation), bipolar cut and coagulation.

Suitable in outpatient surgery, general surgery, pediatric surgery, plastic surgery, thorax surgery, vascular surgery, dermatology, endoscopy, gastroenterology, gyneacology, neurosurgery, orthopedics, otorhinolaringology, pneumology, urology, veterinary

TWIN OPERATIVE ACTIVITY

- two output channels for monopolar cutting

- two independent setting and output channels for the most frequent monopolar coagulation

CONTROLLED CUTTING PROCEDURES

- enhanced cutting current for eschar free incision

- cutting current with selectable coagulating property for bleeding controlled dissection

- low capacitance coupling by slow BLEND current for endoscopic procedures

TWIN CONTROLLED COAGULATION PROCEDURES

- SPEEDY coagulation and DEEP coagulation available to two operators

- SPRAY coagulation by hand switch or foot switch controls

EXTENSIVE BIPOLAR FEATURES

- bipolar cutting current with selectable bleeding control

- slow BLEND cutting current

- automatic Start/Stop coagulation functions

SURGEON AND PATIENT TOTAL SAFETY·

- acceptability of contact impedance between patient body and return electrode continuously monitored by Skin Plate Electronic Control (SPEC)

- H.F. leakage currents continuously monitored

- mains fluctuation automatically compensated before delivery of HF power

PERSONALIZED PROCEDURES

- independent choice of coagulation currents and power levels by each of two operators

- up to 10 procedures can be configured and re-called

EXTENSION DRIVER AND INTERLOCK SIGNALS

- driven output connection to external Argon Plasma unit and Smoke Evacuator unit

AUTOMATIC SELF DIAGNOSIS

- automatic diagnostic control of the complete functionality of electronic unit and connected accessories with coded report of failures

Standard Accessories

  • 1 - Power supply cord 5 m
  • 1 - Two-button autoclavable handle
  • 5 - Two-button cold sterilizable handle
  • 1 - Cable for flat plate
  • 5 - Rem disposable ground pads
  • 2 - HP double Water proof foot switch
  • 3 - Short, general surgery blade electrode 7 cm
  • 3 - Long, general surgery blade electrode 16 cm
  • 3 - Short, general surgery ball electrode Ø 4 mm, 6 cm
  • 1 - Electrode brush
  • 1 - User manual (IT, GB)
  • 1 - Service manual (IT, GB)

N-30634

Specific References

New product

• Maximum out power monopolar pure CUT: 300 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT80%: 250 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT60%: 200 W - 300 Ohm

• Maximum out power monopolar cut-coag CUT40%: 150 W - 300 Ohm

• Maximum out power monopolar cut ENHANCED: 200 W - 500 Ohm

• Maximum out power monopolar cut-coag BLEND: 200 W - 300 Ohm

• Maximum out power monopolar coag SPEEDY: 100 W - 500 Ohm

• Maximum out power monopolar coag DEEP: 100 W - 200 Ohm

• Maximum out power monopolar coag SPRAY 70 W - 2000 Ohm

• Maximum out power monopolar coag SPRAY ARGON: 70 W - 2000 Ohm

• Maximum out power bipolar CUT 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm

• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm

• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm

• Working frequency monopolar/bipolar: 425 kHz / 525 kHz

• Patient circuit: F

• Selectable input voltage: 115-230 Vac

• Mains frequency: 50-60 Hz

• Electrical input voltage: 1000 VA

• Size WxHxD mm: 470 x 150 x 400

• Weight: 17.5 kgs

• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control

• Safety: EN60601-1, EN60601-1-2, EN60601-2-2

• Electrical Class: I CF, MDD 93/42/EC - Class: II b

Contact us

optional

Interested in product

Tell us your interest in this product and we will contact you for more details.

Diatermo MB 300D Hospital Electrosurgical Unit

Diatermo MB 300D Hospital Electrosurgical Unit

WhatsApp Chat