Varian Cary 50 Bio UV-VIS Spectrophotometer
zoom_out_map

Varian Cary 50 Bio UV-VIS Spectrophotometer

31032201
Second Hand
€800.00 Tax excluded
Available

Varian Cary 50 Bio UV-VIS Spectrophotometer

The Varian Cary 50 Bio UV-Visible Spectrophotometer features a data collection speed of 80 points per second; a maximum scan speed of 24,000 nm per minute; the wavelength range of 190-1100 nm is scannable in less than 3 seconds; and measures samples up to 3 Abs. 

WhatsApp Chat

 

Worldwide Delivery

 

After Sales Service Guaranteed

 

Secured Payment

Varian Cary 50 Bio UV-VIS Spectrophotometer

The Varian Cary 50 Bio UV-Visible Spectrophotometer features a data collection speed of 80 points per second; a maximum scan speed of 24,000 nm per minute; the wavelength range of 190-1100 nm is scannable in less than 3 seconds; and measures samples up to 3 Abs. 

Excellent noise performance is achieved due to the highly focused and intense light beam, even when using small aperture microcells. 

The Varian Cary 50's super-focused beam makes it ideal for fiber optic work, offering excellent coupling efficiency and high light throughput.  Its immunity to ambient light makes it unnecessary to shield a fiber optic probe.

31032201

Specific References

Second Hand
  • Grating: Holographic, 27.5 x 35 mm, 1200 lines/mm, blaze angle 8.6° at 240 nm
  • Beam Splitting System: Beam splitter
  • Detectors: Two silicon diode detectors
  • UV-Vis Limiting Resolution (nm): 1.5
  • Toluene/Hexane Limiting Resolution Test: 1.65
  • Stray Light (%T) at 198 nm (12 g/L KCl, TGA and BP/EP method): 0.53%
  • Stray Light at 220 nm (10 g/L NaI ASTM method): 0.02%
  • Stray Light at 370 nm (50 mg/L NaNO2): 0.018%
  • Wavelength Range (nm): 190–1100
  • Wavelength Accuracy (nm): ±0.07 at 541.94 nm, ± 0.24 at 260.54 nm
  • Wavelength Reproducibility (nm): ±0.01
  • Photometric Accuracy (Abs) Using NIST 930D filters at 1 Abs: ±0.0007
  • Photometric Accuracy (Abs) Using NIST 930D filters at 0.2, 0.5 and 0.75 Abs (14.2% w/v KNO3, TGA method): ±0.01,
  • Photometric Accuracy (Abs) Using NIST 930 filters at 0.292 to 0.865 Abs (60.06 mg/L K2Cr2O7, BP method) : 0.01, 0.955 Abs
  • Photometric Accuracy (Abs) Using NIST 930 filters at 0.292 to 0.865 Abs (600.06 mg/L K2Cr2O7, BP method): ±0.012
  • Photometric Range (Abs): 3.3
  • Photometric Display: ±9.9999 Abs, ±200.00 %T