HAMILTON C1 Mechanical Ventilator
zoom_out_map

HAMILTON C1 Mechanical Ventilator

N-RESPI0010

Requiring only a minimum of space, the HAMILTON-C1  mechanical ventilator combines high reliability, ease of use, and maximum mobility with high performance.

 

Worldwide Delivery

 

After Sales Service Guaranteed

 

Secured Payment

This makes it an ideal companion for your ventilated patients in the intensive care unit, emergency ward, recovery room, in intermediate care, and for intrahospital transport. 

The integrated high-performance turbine enables the HAMILTON-C1 to be completely independent from compressed air. In addition, it provides a peak flow rate of up to 260 l/min, guaranteeing optimal performance even in noninvasive ventilation.

The HAMILTON-C1 includes Hamilton Medical's standardized Ventilation Cockpit user interface and the unique intelligent ventilation mode, Adaptive Support Ventilation.

Hamilton Medical's intelligent ventilation mode ASV automatically employs lung-protective strategies to minimize complications such as AutoPEEP and volutrauma/barotrauma. Within the rules of this lung-protective strategy, ASV encourages the patient to breathe spontaneously.

According to several studies, ASV reduces ventilation time in post-cardiac surgery patients, medical patients, and COPD patients. In active patients, ASV decreases work of breathing and improves patient-ventilator synchrony.

In close cooperation with users and ventilation experts, our engineers have designed a user interface that is particularly intuitive. Switching between the  HAMILTON-C1 and all other Hamilton Medical ventilators is easy because they are operated according to the same principles.

The Ventilation Cockpit on the HAMILTON-C1 mechanical ventilator consolidates the monitoring data and converts it into visual displays. These easy-to-understand displays give a quick overview of the patient’s current ventilation status and provides a reliable basis for therapy decisions.

Hamilton Medical ventilators and ASV can reduce ventilation time and thus treatment costs.  They can also reduce the time needed for standard settings and alarm management while maintaining ventilation quality. This frees up time for other aspects of patient care.
 
Thanks to the ease of operation, consistent operating concepts and free e-learning modules from Hamilton Medical, the efficiency of training is also improved.

The HAMILTON-C1 mechanical ventilator provides effective, safe, and lung-protective ventilation for adult, pediatric, and neonatal patients. For neonatal patients, a specifically developed neonatal proximal flow sensor is used. The tidal volume range goes down to 2 ml.

N-RESPI0010

Specific References

Download

Brochure C1

Download (2.09M)

Contact us

optional

Interested in product

Tell us your interest in this product and we will contact you for more details.

HAMILTON C1 Mechanical Ventilator

HAMILTON C1 Mechanical Ventilator

Leave us a message
Hello, our team is not online at the moment. We invite you to send us your request via our contact section. It will be processed as soon as possible.